Products
Grants & Rebates
Tips & Advices
Customer Testtimonials
About Us
Contact Us
Heaters by Schwank  

supraSchwank

The most efficient infra-red heater in the world (world-wide patents pending)

Comparison

The unique, ultra high efficiency supraSchwank 30 heater with an input of 88,500 BTU/hr. has the same infra-red output as a conventional radiant heater with 180,000 BTU/hr. input.

The industry invariably uses the commonly accepted gas combustion efficiency to rate all its products. The supraSchwank leads the industry with a combustion efficiency of 96%. However, this figure does not relate to the effectiveness of a heater to convert gas input to infra-red energy. Schwank rates its products by measuring the actual infra-red energy delivered to the working level.

The supraSchwank patented heater design converts 81% of the gas input into infra-red energy which heats the working level to the desired comfort temperature. The temperature at the ceiling will seldom exceed that at the working level. By comparison, conventional heaters produce ceiling temperatures as high as 120 degrees Fahrenheit.

Schwank is proud to lead the industry with its latest innovative European design which produces the most infra-red heat to the working level for the lowest fuel cost.

Features Benefits
Combustion efficiency is 96%. Infra-red component of the total heat output is 81%. This is the highest infra-red conversion of any heater in the world.
  • Lowest operating costs
  • Lower installation costs
    • Fewer heaters
    • Gas pipe sizes smaller
Innovative insulated construction reduces convection heat loss.
  • Less heat energy lost at ceiling level.
Produces and emits high-and-low-intensity infra-red rays.
  • Full spectrum of infra-red rays utilizing their unique characteristics are directed to the application.
Unique Delta Mixing Chamber design produces precise pressurized gas/air combustion mixture.
  • Uniform, complete and clean combustion across entire surface of heater for high efficiency.
Burner design reduces pollution products.
  • Negligible NOx from an environmentally friendly appliance. Produces maximum, safe, comfortable heat.
Venturi tube built into insulated double wall of reflector: Preheats combustion air Insulates reflector
  • Increases efficiency
  • Permits smaller clearances above the heater
Each heater has only one burner, dedicated ignition, and sensing system.
  • Ultimate safety and fuel economy.
  • Eliminates possibility of non-ignition as in conventional multi-burner designs.
  • Time proven, reliable design for industrial environments.
Full operating temperature, and safe cool-down, reached in 60 seconds.
  • No long inefficient warm-up periods..
Ceramic tile modules identical throughout entire range of Schwank heaters, both high-and low-intensity.
  • Time proven, environmentally friendly, high efficiency design.
Aluminum, cold-bonded clad steel enclosure and advanced press-joint construction.
  • Entraps heat and permits full utilization of heat previously lost.
  • Withstands corrosion for longer life.
Refractory mesh reclaims energy from entrapped convection heat.
  • Increases efficiency and infra-red heat output.
Suitable for natural or LP gas.
  • Universal application.

Engineering Specifications

Unmatched selection

Model
Input BTU/Hr.
Infra-Red Primary
SupraSchwank10
(normal and high altitude) 29,500
(Output* BTU/hr.)
23,900
SupraSchwank 15
(normal and high altitude)
44,000
(Output* BTU/hr.)
35,600
SupraSchwank 20
(normal and high altitude) 59,000
(Output* BTU/hr.)
47,800
SupraSchwank 30
(normal and high altitude) 88,500
(Output* BTU/hr.)
71,700

Definition

* (IR Primary Output means the certified infra-red primary BTU's delivered to the work place. Heater delivers full spectrum of infra-red energy from high- to low-intensity. The unique characteristics of these different intensity wavelengths can be applied to a wide range of applications.
(Certification data available from Schwank.)

Minimum Clearance to Combustibles
Minimum Clearance to Combustibles

Minimum Clearance to Combustibles


Model
A
Weight
SupraSchwank10
23 7/8"
37 lbs.
SupraSchwank 15
34 1/2"
53 lbs.
SupraSchwank 20
45 3/4"
62 lbs.
SupraSchwank 30
67 1/2"
82 lbs.

Nat. Gas
LP Gas

Line min. in. WC
6
12
Line max. in. WC
14
14
Manifold. in. WC
5
11
Gas Pipe size in.
0.5
Voltage 24 v
Current .0.55 A

 

 

 

askus@bayridgeheating.com | Phone: (604) 219 7740 | Fax: (604) 542 1465

 